Home Battery Arbitrage

2D companion of the 3D home battery lab: charge when the grid is cheap, discharge when it is dear, and see what the efficiency loss costs.

Switch to 3D

Presets

Playback

Apparatus

Model checks

The science

What is modelled

A home pays a different price per kWh in three bands. A battery buys energy in the cheapest band and returns it into the household load in the dearest band. Because some energy is lost each cycle, it only pays when the price ratio beats the round-trip efficiency.

Equations

  • One-way efficiency η = √(round-trip); state of charge SOCh+1 = SOCh + η ch − dh/η.
  • Grid power gh = Lh − dh + ch, bill ∑ ph gh.
  • Dispatch rule: charge (up to the power and capacity limits) in the cheapest hours, discharge only into the load in the dearest hours, and only if pmax · ηrt > pmin.

Checks run in the page

  • Energy ledger: grid import and state-of-charge change against charge and discharge.
  • Bill ledger: the two running bills against price x (discharge − charge) hour by hour.
  • Break-even rule and limits: no cycling below the efficiency threshold, periodic state of charge, power and capacity respected.

Honest simplifications

Prices are fixed per band, the dispatch is a simple rule (not an optimiser), there is no export tariff, battery ageing or standing charge, and the load is a smooth made-up profile, not a measured one.

What to try
  • Press Flat tariff, no gain: with equal prices the battery idles and the saving is zero.
  • Press Poor battery (80 %): the spread is too small for the losses, so nothing is cycled.
  • Press Evening-heavy, big spread and compare the saving with the typical home.
Tariff against hour
Load and grid power with battery
Battery state of charge
Daily saving against peak price