Presets
Playback
Apparatus
Model checks
The science
What is modelled
A home pays a different price per kWh in three bands. A battery buys energy in the cheapest band and returns it into the household load in the dearest band. Because some energy is lost each cycle, it only pays when the price ratio beats the round-trip efficiency.
Equations
- One-way efficiency
η = √(round-trip); state of chargeSOCh+1 = SOCh + η ch − dh/η. - Grid power
gh = Lh − dh + ch, bill∑ ph gh. - Dispatch rule: charge (up to the power and capacity limits) in the cheapest hours, discharge only into the load in the dearest hours, and only if
pmax · ηrt > pmin.
Checks run in the page
- Energy ledger: grid import and state-of-charge change against charge and discharge.
- Bill ledger: the two running bills against price x (discharge − charge) hour by hour.
- Break-even rule and limits: no cycling below the efficiency threshold, periodic state of charge, power and capacity respected.
Honest simplifications
Prices are fixed per band, the dispatch is a simple rule (not an optimiser), there is no export tariff, battery ageing or standing charge, and the load is a smooth made-up profile, not a measured one.
What to try
- Press Flat tariff, no gain: with equal prices the battery idles and the saving is zero.
- Press Poor battery (80 %): the spread is too small for the losses, so nothing is cycled.
- Press Evening-heavy, big spread and compare the saving with the typical home.