Column model. ε ∂c/∂t + ρb ∂q/∂t + u ∂c/∂z = ε D ∂²c/∂z², uptake ∂q/∂t = k (q* − q), competitive Langmuir q* = qmax KLi c/(1 + KLi c + KNa cNa) (the isotherm plot shows how sodium lowers the capacity), Arrhenius rate k = k25 exp[Ea/R (1/298 − 1/T)]. Finite-volume upwind with an implicit cell-wise uptake step: exactly conservative and stable at any rate constant.
Cycle. Adsorb until the outlet reaches the chosen fraction of the feed, swap, then strip the loaded column with fresh eluent (isotherm weakened 50×). The concentration factor is the eluate Li divided by the feed Li; 1 g Li gives 5.32 g Li2CO3.
Honest simplifications. One lumped sorbent and one lumped competitor, constant bed, no pH, scaling or sorbent ageing, perfect elution switch, no heat balance or costs. Parameters (8 mg/g, K = 0.02 L/mg) are illustrative. Sprites were rendered in Blender.
Independent checks (run on load):
| running… |