What is modelled
Every building has a one-off carbon cost to make the materials and build it (embodied carbon) and a yearly cost to heat, cool and light it (operational carbon). If one building is cheaper to build but dearer to run, the cumulative totals cross at some year, or never within the life of the building.
Equations
- Grid factor
q = 1 − dper year; operational emission in year k iso qk. - Cumulative operation
S(t) = (1 − qt) / (−ln q), which tends totwhen the grid stays dirty. - Total
C(t) = E + o S(t); the timber building carries the creditEt − stored carbon. - Crossover where
S* = (Ec − Et) / (ot − oc), att* = ln(1 − S* (−ln q)) / ln q; ifS*exceeds the limit1/(−ln q)the curves never meet.
Checks run in the page
- Analytic crossover against bisection.
- Closed-form operation against year-by-year bookkeeping.
- The constant-grid limit.
- The derivative of the crossover year against the embodied carbon.
- The end-of-life difference of the two totals.
Honest simplifications
The numbers are round illustrative values per square metre, not an assessment of any real building. There is no maintenance, replacement, end-of-life or discounting, and the storage credit is simply deducted. A real life-cycle assessment uses standard modules and measured data.
What to try
- Press Fossil grid forever and Clean grid soon and compare the crossover years.
- Press Timber thermal penalty and watch the crossover come much earlier.
- Press With storage credit: timber starts so far ahead that the curves may never meet in the lifetime.