PC Thermal Lab (2D)

Run a boost-and-sustain load test and see junction temperature, clocks, case air, noise and PSU load.

Switch to 3D

Presets

Playback

Room and CPU

Ambient and processor power limits (PL2 boost for tau seconds, then PL1).

Cooling

Thermal paste and case airflow.

GPU and PSU

Options

Layers

Model checks

The science

Thermal resistance chain

Heat from the CPU die flows through a series of thermal resistances: Tj = T_air + P (R_jc + R_paste + R_sa). R_jc is die to heat spreader, R_paste the thermal interface (conductivity k, thickness t, contact coverage), and R_sa the cooler fin stack to case air, which falls as the fan speeds up (R_sa = R_cond + 1 / (g0 + g1 (rpm/rmax)^0.8)). The paste term is R = t / (k A) + contact resistance; too little paste leaves air-filled voids, too much makes the layer thick.

Transient and throttling

The die and cooler are two thermal masses (C dT/dt = P_in - P_out, explicit Euler with a step much smaller than the time constants), so the processor can run at its boost limit PL2 for a time tau before settling at PL1. Above 95 C the power is cut; above 105 C for 2 s the system shuts down. Dynamic power goes roughly as P ~ f^3, so clock f = f0 (P/PL1)^(1/3).

Case air and PSU

Case air rises by ΔT = P / (rho c_p Q) where Q is the fan flow through filters and mesh. The PSU draws P_wall = P_dc / eta(load) from an 80 PLUS Gold-class efficiency curve that is lowest at light load.

Simplifications

Illustrative constants for a mid-range desktop build, not measurements of any product; no multi-core hot spots, no VRM or SSD thermal model, constant ambient.

What to try
  • Set paste to 0 mg and watch Tj jump; then try 200 mg (pea-size) and 500 mg.
  • Raise PL1 to 160 W with a 34 C room: the cooler saturates and the clock throttles.
  • Remove the rear fan and compare the case air temperature.
  • Sweep the GPU power and watch the PSU load and wall power.
Temperatures versus time (C)
CPU power and clock versus time
Paste resistance versus paste mass
PSU efficiency curve and operating point