Tesla Coil Resonance Lab (3D)

A Blender-built coil on a lab bench: capacitor bank, spark gap, primary spiral, secondary winding and toroid driven by the live circuit solution.

Presets

Playback

Primary circuit

Capacitor, inductor and charging voltage.

Secondary and top load

Secondary inductance, toroid size and coupling.

Run

Playback speed, shot length and spark gap behaviour.

Camera

Layers

Quality

Model checks

The science

Two coupled resonant circuits

The primary is a capacitor C1 discharged through a spark gap into the inductor L1; the secondary is a tall coil L2 whose only capacitor is the toroid (C2 = 2 pF of coil self-capacitance + 4 pi eps0 R for a sphere of the toroid radius). With mutual inductance M = k sqrt(L1 L2) the two loop equations are L1 di1/dt + M di2/dt = q1/C1 - R1 i1 and M di1/dt + L2 di2/dt = -q2/C2 - R2 i2, integrated here with fourth-order Runge-Kutta. Total energy E = L1 i1^2/2 + M i1 i2 + L2 i2^2/2 + q1^2/2C1 + q2^2/2C2 falls only by R1 i1^2 + R2 i2^2.

Why the voltage rises

If all the energy C1 V0^2 / 2 is handed to the secondary, C2 V2^2 / 2 = C1 V0^2 / 2, so V2 = V0 sqrt(C1/C2). With f1 = f2 the energy sloshes between the two circuits at the beat frequency f+ - f-, where the exact lossless normal modes solve (L1 L2 - M^2) w^4 - (L1/C2 + L2/C1) w^2 + 1/(C1 C2) = 0 (for tuned circuits w = w0 / sqrt(1 +/- k)). Complete transfer happens after half a beat; a spark gap that opens at that first notch (“quenching”) stops energy flowing back into a lossy primary.

Detuning and loss

Move L2 away from the value that makes f2 = f1 and the transfer is incomplete: the resonance scan graph shows the peak V2 against the L2 scale factor. Resistance R1, R2 dissipate energy each cycle, so the secondary voltage is lower and decays.

Arcs

The top load starts to emit corona when the surface field V2 / R reaches about 3 MV/m (the breakdown field of air). A streamer then grows roughly one metre per 0.5 MV; the arc length shown is (V2 - 3 MV/m x R) / 0.5 MV/m, an order-of-magnitude rule, not a prediction.

Honest simplifications

Lumped circuit model: no skin effect or proximity loss changing with frequency, no top-load or streamer loading of the secondary (real streamers add capacitance and lower f2), constant coupling, an ideal gap that closes instantly at full voltage and quenches when the primary energy is below 3% of the start. The streamer drawing is decorative: its length follows V2(t) but its shape is random. Not an operating guide: real coils run at lethal voltages and currents.

What to try

  • Press Detuned secondary: the peak V2 falls and the beat pattern breaks. Find the green f1 = f2 marker on the resonance scan.
  • Slide the coupling k up: the two normal modes split apart, and the beat period shortens (graph 3).
  • Switch to Gap never quenches and watch energy return to the primary (graph 2).
  • Shrink the toroid: capacitance falls, the gain sqrt(C1/C2) rises, but corona onset voltage falls too.
  • Raise R2 and read the energy that reaches the secondary and the arc estimate.
Loading model...
Loading Blender model...
Normalised capacitor voltages (V1/V0 and V2/ideal)
Energy in primary, secondary and dissipated (J)
Normal-mode frequencies against coupling k
Resonance scan: peak V2 against L2 scale factor
Made with 🟠 Blender · Three.js