Voltage response
Higher field increases electrical migration, within the simplified model.
INDUSTRIAL AIR CLEANING / 01
An electrostatic precipitator separates fine particles from moving gas by charging them and drawing them onto grounded collector plates.
02 / PARTICLE MIGRATION
04 / EXPLORE THE RESPONSE
Higher field increases electrical migration, within the simplified model.
The ideal model gives an exponential decline in suspended dust.
The slip correction matters most as particle size approaches the gas mean free path.
A particle with effective charge q experiences force F = qE. Balancing this against Stokes drag with the Cunningham slip correction gives the migration speed used here.
The Deutsch–Anderson idealisation treats collection as an exponential depletion of suspended particles over an effective collecting area.
Uniform average field, fixed effective particle charge, spherical particles, dilute dust loading, Stokes-regime drag with slip correction, ideal plate collection, and no re-entrainment, particle-size distribution, gas turbulence, electrical breakdown or back corona. Values are illustrative, not a plant design calculation.
Viscosity varies with temperature using Sutherland’s law. The effective charge is a direct input rather than a corona-charging prediction. Displayed operating values are illustrative; equations follow textbook idealisations and the schematic is not to scale.
Illustrative design, not affiliated with any real institution or manufacturer.