EP
Mechanical study · inspection edition
The electrostatic chamber
LIVE MODEL / r160Open 2D analysis ↗
Electromagnetism / gas cleaning

Inside the capture field.

Illustrative values · scaled assembly · orbit to inspect · select a part to isolate it

OVERVIEW / INSPECTION
Preparing inspection scene · 3 second camera arrival
Collection efficiency
83.0%
Ideal single-pass estimate
Migration velocity
189.8mm/s
Stokes mobility with slip
Electric field
266.7kV/m
Voltage divided by gap
Residence time
0.84s
Active length / gas speed

Collector plates

Grounded collecting surfaces attract charged dust particles. Deposited material is periodically removed from the plate faces.

Model check

Independent numerical integration is being calculated.

The science · equations and assumptions

Electric field and particle mobility feed the ideal Deutsch–Anderson single-pass collection relation.

E = V / g
w = q E Cc / (3 π μ dp)
η = 1 − exp(−w A / Q),   A = 2 H L

The effective particle charge is imposed, not generated by a corona-discharge charging model. The 3D scene is visually compressed; reported values use the labelled SI dimensions. Reference air properties: μ = 1.81 × 10⁻⁵ Pa·s and mean free path = 66 nm. Turbulence, re-entrainment, nonuniform fields and plate fouling are omitted.