Electromagnetism / gas cleaning
Inside the capture field.
Illustrative values · scaled assembly · orbit to inspect · select a part to isolate it
Collection efficiency
83.0%
Ideal single-pass estimate
Migration velocity
189.8mm/s
Stokes mobility with slip
Electric field
266.7kV/m
Voltage divided by gap
Residence time
0.84s
Active length / gas speed
Collector plates
Grounded collecting surfaces attract charged dust particles. Deposited material is periodically removed from the plate faces.
Model check
Independent numerical integration is being calculated.
The science · equations and assumptions
Electric field and particle mobility feed the ideal Deutsch–Anderson single-pass collection relation.
E = V / g
w = q E Cc / (3 π μ dp)
η = 1 − exp(−w A / Q), A = 2 H L
The effective particle charge is imposed, not generated by a corona-discharge charging model. The 3D scene is visually compressed; reported values use the labelled SI dimensions. Reference air properties: μ = 1.81 × 10⁻⁵ Pa·s and mean free path = 66 nm. Turbulence, re-entrainment, nonuniform fields and plate fouling are omitted.