Cobalt Electrowinning: Faraday Plating, Tafel Kinetics and Hydrogen Losses

Plate cobalt onto steel cathodes: current efficiency, cell voltage and energy per kilogram change with current density, pH, cobalt level and stirring.

Switch to 2D

Presets

Playback

Parameters

Camera

Layers

Quality

Model check

The science

What you see. A cobalt electrowinning cell: four stainless-steel cathodes hang between five lead-alloy anodes in a pink cobalt-sulphate electrolyte. Current drives Co2+ + 2e− → Co on the cathodes (silver layers that grow, drawn about 12 times thicker than real) while oxygen forms at the anodes and some of the current is wasted as hydrogen at the cathodes.

Faraday and efficiency. The deposited mass is m = ηc I t M / (n F) with M = 58.93 g/mol, n = 2, F = 96 485 C/mol. The current efficiency ηc is the share of the current that makes cobalt, iCo / j. Both reactions run at the same cathode potential E; the model finds it by bisection so that iCo(E) + iH(E) = j.

Kinetics. Each partial current follows a Tafel law i = i0 exp[−αF (E − Eeq)/RT] with α = 0.5, so the potential changes by 2.303 RT/(αF) ≈ 118 mV per decade of current at 25 °C. The equilibrium potentials are ECo = −0.28 V + (RT/2F) ln c and EH = −(2.303 RT/F) pH. The cobalt current is capped by diffusion: 1/iCo = 1/ikin + 1/ilim with ilim = 2 F km c, so a depleted or unstirred electrolyte pushes the cathode to the hydrogen potential. A lower pH raises EH by 59 mV per unit and makes hydrogen easier, which is why industrial cells hold the pH around 3–5 and add buffers and base.

Cell voltage. U = EO2 − E + j d/κ + Uother: the oxygen-evolution potential (with an overpotential of 0.35 V at 100 A/m² and 120 mV per decade), the cathode potential, the ohmic drop across the gap d with electrolyte conductivity κ, and 0.25 V for contacts. Energy per kilogram is U n F / (ηc M).

Honest simplifications. The exchange current densities (2 A/m² for cobalt, 0.02 A/m² for hydrogen), the activation energy, the mass-transfer coefficient and the conductivity law are illustrative, not measured for a real plant. Activity is set equal to concentration; there is no cobalt hydroxide precipitation, no boric-acid buffer, no additives, no anode mist, no current-distribution effects at plate edges, and the electrolyte is perfectly mixed. Deposit morphology is not modelled. Use it to see how current, pH, cobalt level and stirring trade off, not to design a cell.

Checks. (1) Faraday's law with hydrogen switched off, against the exact I t M/(nF) for mass, electrolyte loss and thickness; (2) the current balance of the bisection over 400 random cells; (3) the Tafel slope and the Nernst shift of the model against their analytic values; (4) energy per kilogram in the no-hydrogen limit against U n F / M.

Loading model...
Loading Blender model...
Polarisation curves (potential against current)
Current efficiency against current density
Electrolyte cobalt and efficiency over time
Made with 🟠 Blender · Three.js