Thomson e/m Experiment Simulation: Electron Charge-to-Mass Ratio in a Helmholtz Coil Fine-Beam Tube (3D)

Two copper coils, a glowing helium beam and a rack of meters.

Switch to 2D

Presets

Playback

Electron gun and coils

The current sets the magnetic field.

Coil geometry

Turns, radius and a stray axial field.

Gas in the tube

Gas makes the beam visible.

Gun and glow

Tilt the gun to get a helix.

Measurements

Record ruler readings like a student laboratory.

Camera

Layers

Quality

Model checks

The science

How the electron's charge-to-mass ratio is measured

Electrons accelerated through a voltage V gain kinetic energy e V = ½ m v², so they leave the gun with speed v = sqrt(2 e V / m) (the simulation includes the small relativistic correction through the Lorentz factor γ). In a magnetic field B at right angles to the motion the force F = -e v × B is always sideways, so the electron moves on a circle:

γ m v² / r = e v B => r = γ m v / (e B)

Eliminating v gives the classic result J. J. Thomson's tube was built to measure:

e / m = 2 V / (B² r²)

The Helmholtz pair

Two identical coils of radius R placed a distance R apart give an almost uniform field in the middle: B = (4/5)^(3/2) μ₀ N I / R. Away from the centre the field is not exactly uniform; the program integrates the Biot-Savart law around both loops numerically to get the mid-plane field profile and integrates the electron path with a fourth-order Runge-Kutta method, so a large orbit really does feel the weaker field near the coils.

The orbit period T = 2 π γ m / (e B) does not depend on the radius, which is why electrons launched at different speeds all come back to the gun after the same time.

Honest simplifications

The gas that makes the beam glow is not simulated as collisions (no energy loss or beam spreading); the field is taken to be purely axial; space-charge repulsion inside the beam is ignored; the gun is a point source and the voltage is exactly V. The ruler reading is rounded to 1 mm, like a real graticule, so single readings scatter by a percent or two. The Earth's field is entered as a residual axial component; real laboratories cancel it with a third coil pair.

What to try

  • Press Record a reading several times at different voltages and currents: the readings scatter around 1.76 x 10^11 C/kg, as in a student laboratory.
  • Double the current and watch the radius halve; raise the voltage fourfold and watch it double.
  • Switch on the +45 uT residual field and see the error appear in every reading.
  • Use the big-orbit preset: the orbit reaches the weaker field near the coils and the estimate drifts.
  • Tilt the gun and see the circle become a helix, whose side view is still a circle of the same radius.
Loading model...
Loading Blender model...
Orbit radius versus coil current
Orbit radius versus accelerating voltage
Recorded e/m readings
Field profile of the Helmholtz pair
Made with 🟠 Blender · Three.js