Flux loop in the laminated core, coil currents, eddy loops in the plates, waveforms and efficiency against load.
Checks the energy balance, Faraday's law by numerical integration of the emf, the eddy-loss formula by quadrature across the plate, and the turns ratio at near-no-load.
Not run yet.
The science
Faraday. The secondary voltage is the rate of change of flux linkage. For a sinusoidal supply the peak flux density is Bpk = √2 E / (2π f N1 Ac), i.e. E = 4.44 f N1 Ac Bpk; the open-circuit voltage ratio is N2/N1. Too few turns or too low a frequency drives the core into saturation.
Magnetisation. A smooth single-valued soft-iron curve B = Bs tanh(μ0μrH / Bs) sets the non-linear magnetising current; its fundamental gives the magnetising reactance.
Losses. Copper loss is I²R with R from wire length and cross-section. Core loss is hysteresis kh f Bα per kg plus classical eddy loss π² σ t² f² B² / (6ρ) per kg, which grows with the square of the lamination thickness t: thin insulated plates make the eddy loops (inset) small.
Equivalent circuit. Primary resistance and leakage in series, magnetising branch (Rc parallel Xm) in parallel with the referred secondary and load, solved in complex phasors with a few iterations because B depends on the internal emf.
Independent checks. Energy balance Pin = Pout + Pcu + Pfe; Faraday by integrating the emf numerically over half a cycle; the eddy-loss formula re-derived by quadrature of σEy² across the plate thickness and the cycle.
Simplifications. Single-valued B–H curve (loss from a separate empirical term, no hysteresis loop), no skin effect, no inter-winding capacitance, uniform flux in the core, generic material constants. The physics module is the one used by the 3D page. Educational, not a design tool.