Electric Motor Field — 2D

A permanent-magnet DC motor: Lorentz force on the armature, back-EMF, torque-speed line and efficiency.

Switch to 3D

Presets

Playback

Parameters

Layers

Model checks

The science

A conductor of length l carrying current i in flux density B feels the Lorentz force F = B i l; summed over the armature this is a torque τ = Kt i. The rotating conductors also generate a back-EMF e = Ke ω (Ke = Kt in SI units).

Electrical side: V = Ra i + L di/dt + Ke ω. Mechanical side: J dω/dt = Kt i − bω − τc sign(ω) − τload. At steady state ω = (KtV/Ra − τload − τc) / (Kt²/Ra + b): a straight torque-speed line from stall torque KtV/Ra to no-load speed V/Kt. The speed settles with the mechanical time constant J / (b + Kt²/Ra).

Simplifications: ideal commutation (constant Kt), no brush drop, no armature reaction or magnetic saturation, constant Coulomb friction of 0.01 N m, load modelled as a pure torque.

What to try
  • Start from rest: the current spikes towards V/Ra and falls as the back-EMF rises.
  • Press Kick load: speed dips, current rises, then both recover.
  • Compare light and heavy flywheel: same final speed, different time constant.
  • Move the load torque and watch the operating point slide along the torque-speed line; efficiency peaks at moderate torque.
Speed and armature current against time
Motor torque against load plus friction torque
Torque-speed line and operating point
Efficiency against torque