Pressure makes a pathway
Two connected air paths form a loop: a warm central shaft and cooler peripheral flutes. The model combines stack pressure with wind pressure, then sends air through an effective porous resistance.
Δp = ρgH (Tcore − Tflute) / T̄ + ½ρCpv² cos θ
Q = (kA / μL) · (1 − b) · Δp
Heat and nest air
Cn dTn/dt = Pcolony − Gn(Tn − Tsoil) − ρcp|Q|(Tn − Tf)
V dCCO₂/dt = |Q|(Cout − CCO₂) + RQ·Pcolony / EO₂
Thermal and CO₂ states are integrated with fixed-step fourth-order Runge–Kutta. Airflow is quasi-steady Darcy flow through an effective path; flow direction follows the sign of Δp.
Species-specific evidence
There is no single universal termite-mound ventilation mechanism. Wind-driven, reversing (“tidal”) air movement was measured in Macrotermes michaelseni (Turner, 2001, Physiological and Biochemical Zoology 74:798–822; DOI 10.1086/323990). Diurnal solar heating of outer flutes driving a convection cell was measured in Odontotermes obesus (King et al., 2015, PNAS 112:11589–11593; DOI 10.1073/pnas.1423242112). This exhibit combines wind and buoyancy in a deliberately simplified two-path network.
Independent stack-pressure check
ENGINE · LINEARISED STACK0.427 Pa
IDEAL-GAS HYDROSTATIC0.427 Pa
RELATIVE DIFFERENCE0.02%
The check compares the engine's linear stack approximation with the closed-form pressure difference between two isothermal ideal-gas columns at equal base pressure. Textbook constants: g = 9.80665 m/s², p₀ = 101325 Pa, Rair = 287.05 J/(kg·K), μ = 1.81 × 10⁻⁵ Pa·s, cp = 1005 J/(kg·K), and EO₂ ≈ 20.1 kJ/L.
Scaled geometry: H = 2.2 m, A = 0.45 m², L = 1.2 m, V = 0.60 m³. Thermal capacities and conductances are scaled. Illustrative parameters: wind coefficient, respiratory quotient, ambient and soil temperatures, heat inputs and the 2.0% CO₂ teaching line. Real mounds differ by species, architecture, weather and soil.
Illustrative educational model, not affiliated with any real institution or manufacturer.