Accuracy starts with a ruler
Choose a chip, move the right jaw to its farthest tip and record the length to the nearest 0.1 mm. Each chip is drawn at a calibrated scale in the measurement view.
Welcome to the microplastic sorting laboratory. Measure tiny model fragments, sort them by length and watch a real dataset take shape.
Every chip on the filter is a model specimen. Select it, measure the longest dimension, then file it in the correct size band.
Illustrative filter with varied particle sizes.
Nine freshly generated exercises per round — calculations, comparisons and hands-on instrument missions.
Prepare for your first evidence question.
9 challenges to solve. Every correct answer adds to your score.
Use your evidence to describe the sample. These are simulated measurements, not claims about pollution in any named place.
| PARTICLE | SHAPE | LENGTH | SIZE CLASS |
|---|---|---|---|
| Record your first measurement to begin the log. | |||
Only counted particles appear in your chart. Reveal the entire synthetic sample to compare your observations with its true size distribution.
Choose a chip, move the right jaw to its farthest tip and record the length to the nearest 0.1 mm. Each chip is drawn at a calibrated scale in the measurement view.
A length of 2.4 mm belongs in the 2–3 mm bin. The bar chart shows how often each class occurs. The mean adds all recorded lengths and divides by their count.
Real researchers measure and categorise particles to understand environmental samples. To confirm that an object is actually plastic, they may need additional chemical tests.
Definition: The simulated objects are 0.2–4.9 mm long. Microplastics are generally defined as plastic particles less than 5 mm in size; in this simplified display, length means the particle’s longest projected dimension.
Model: Each preset generates 24 independent synthetic sizes using an explicitly hypothetical weighted mix of 1 mm bands. Within each band the model chooses a length in 0.1 mm steps. The precise sizes are known to the computer, but require manual calliper alignment for the learner to record.
Equations: Frequency in band b = number of classified lengths in that band. Mean = sum of lengths ÷ number measured. Median = middle ordered observation (or average of two central values). Range = maximum − minimum. Sorting rule: a size belongs to band b when b ≤ length < b+1 mm.
Assumptions: The microscope and scale are idealised, size readings are rounded to 0.1 mm, each object is separately visible, and a reading must agree with the calibrated length to the nearest 0.1 mm. The colours and shapes do not establish polymer identity. Preset distributions are teaching examples, not estimates for a real beach, stream or water sample. Sorting alone cannot confirm chemical composition or real environmental concentration.
Further reading: NOAA Marine Debris Programme · Microplastic sampling and reporting manual.