What is modelled
A black smoker: seawater that has percolated through the crust, been heated to about 350 °C and loaded with dissolved iron, copper and zinc sulfides, jets out of a chimney on the deep seafloor. On meeting 2 °C seawater the metals precipitate as fine black particles (the smoke) and a fraction of them is deposited on the chimney, which therefore grows upward. The hot, light fluid rises as a turbulent buoyant plume, entrains seawater and dilutes until it is no lighter than its surroundings, hundreds of metres above the vent. The chimney model and the plume model are coupled through the same orifice: radius, exit speed and temperature.
Equations
- Source:
Q0 = π r² v,M0 = Q0 v,F0 = Q0 g′with reduced gravityg′ = g (ρa − ρv(T)) / ρa. The fluid density comes from rounded steam-table values for water at 25 MPa (about 625 kg/m³ at 350 °C) scaled to the density of deep seawater. - Plume (Morton, Taylor and Turner 1956, top-hat profile):
dQ/dz = 2α√(πM),dM/dz = F Q / M,dF/dz = −N² Q, radiusb = Q/√(πM), speedw = M/Q. Integrated with a fourth-order Runge-Kutta scheme until the momentum flux reaches zero: that height is the neutral-buoyancy (rise) height, which scales asF1/4 N−3/4. - Heat output:
P = Q0 ρv (hv − ha)with the enthalpy difference from the same rounded tables (about 1650 kJ/kg at 350 °C), typically several to tens of megawatts for one chimney. - Chimney growth: the mass of sulfide deposited on the chimney is
f Q0 ρv C W(f deposited fraction, C dissolved metal, W molar mass). The chimney is a tapered shell, radiusR(h) = R0 − s h, sodh/dt = f Q0 ρv C W / [ρs (1 − φ) π (R(h)² − r²)], with sulfide density ρs = 4200 kg/m³ and porosity φ = 0.35. - Smoke concentration at height z: the particles not deposited,
(1 − f) Q0 ρv C W / Q(z), is diluted by the growing volume flux Q(z).
Checks run in the page
- Dimensional similarity: halving N must raise the rise height by 23/4.
- RK4 step halving (0.25 m against 0.125 m) and the buoyancy budget
F + N²∫Q dz = F0. - Ninety days of chimney growth: the deposited mass against the closed-form wall volume times density.
Honest simplifications
Top-hat plume with a constant entrainment coefficient and a uniform stratification; real plumes are bent by currents, have density that depends on salinity and pressure, and a phase separation (boiling) is ignored at 400 °C. The bottom-current slider only advects the particles sideways as passive tracers. Metal precipitation is instantaneous, the deposited fraction is a single number, chimneys also grow by anhydrite and are re-dissolved when cooled, and the model stops at the 6 m of the 3D chimney. The far field of the plume is drawn 20 times faster than real time so that it moves visibly. Tubeworms, crabs and mussels are decoration that does not feed back on the physics.
What to try
- Lower the temperature to 250 °C: the fluid is much denser, so buoyancy flux and rise height fall steeply.
- Choose Weak stratification: the same vent now rises far higher than with Strong stratification.
- Raise the metal content and deposited fraction and speed up the growth time-lapse to watch the chimney tower and the growth curve flatten as the cross-section shrinks.
- Move the probe height from 0.1 m to 200 m and read how temperature, speed and smoke concentration fall.
- Use the Whole plume camera with a bottom current.