Geyser Cycle in Section: Chamber, Water Column, Flash Eruption and Steam Phase

Vertical section of a geyser over a Blender-rendered rock and boardwalk scene: the same Clausius-Clapeyron, eruption and refill solver and four checks as the 3D page.

Switch to 3D

Presets

Playback

Parameters

Layers

Model check

The science

What you see. A cutaway of a geyser plumbing system: a heated chamber at the bottom, a 21 m conduit, and a sinter mound around the vent with a viewing boardwalk. Water colour is its temperature. The picture scale is 1 unit = 2 m vertically and the conduit is drawn about four times too wide so the water level can be read.

Why deep water must be hotter to boil. The boiling point rises with pressure. Between the Clausius-Clapeyron law ln(P/P0) = (L/R)(1/T0 − 1/T) and the weight of the column, P = Patm + ρ g h, the chamber must reach about 134 C under a full 21 m column. It is heated by ρ cp V dT/dt = Q − G (T − Tf), so it approaches a plateau of Tf + Q/G with a time constant ρ cpV/G.

The eruption. When the chamber exceeds the boiling point at its depth by a small nucleation superheat, steam forms. A mass of steam below the water column pushes it up like a piston: ρ A Lc dv/dt = A (Psat(Tc) − Patm − ρ g Lc) − friction. As the column rises it gets shorter (water spills out of the vent), so its weight falls much faster than the chamber pressure does (the chamber cools by only about 0.02 K per metre because the latent heat comes from the water): a runaway that throws the whole column out, with exit speed set by v² = 2g∫y/(H−y) dy plus overpressure and friction. The ideal jet height is v²/2g with no air drag.

Steam phase and cycle. After the water has gone, the still superheated chamber water boils off through the vent at the choked mass flow rate until it is down at 100 C. Recharge then refills the conduit at a fixed rate while the chamber reheats; the next eruption starts when the column is deep enough for boiling to occur at the current temperature, so the interval depends on heat input, recharge and nucleation.

Honest simplifications. One well-mixed chamber with constant volume; no two-phase flow or bubbly mixture in the conduit (the real jet is a foam, so heights are upper bounds); constant latent heat in the Clausius-Clapeyron law (about 1 K error at 10 bar); a constant Darcy friction factor; the steam phase is an energy and choked-flow estimate; no side-cavity bubble traps, no mineral scaling, no tidal or barometric effects, and Old Faithful's own parameters are not claimed. A failed eruption (column falls back) is allowed and counted.

Checks. (1) the Clausius-Clapeyron saturation temperature against steam-table values; (2) the piston equation of motion against its closed-form solution for a constant overpressure; (3) the chamber heating law against the exact exponential; (4) the ideal-gas steam density used for the flash volume against steam-table specific volumes.

Ready.
Chamber temperature and boiling point
Column speed during the eruption
Saturation temperature against pressure
Made with 🟠 Blender · Three.js