The science

Signal detection. A static analyser gives every finding a score. Real vulnerabilities score N(d, 1), false alarms N(0, 1); d (d-prime) measures how well the tool separates them. A gate flags a finding when its score exceeds t, so recall = TPR = Φ(d - t) and FPR = Φ(-t). The ROC curve plots TPR against FPR as t sweeps; its area is Φ(d/√2), the chance that a random real finding outscores a random false alarm.

Base rate. What a developer feels is precision, from Bayes: precision = π·TPR / (π·TPR + (1-π)·FPR). When real vulnerabilities are rare (small π) even a good scanner produces mostly false alarms. That is the base-rate fallacy, and the reason “99 % accurate” tools still drown teams in noise.

Choosing the gate. With a review cost of 1 unit per false alarm and cm units per missed vulnerability the cost per finding is C(t) = π cm (1 - TPR) + (1 - π) FPR. Setting dC/dt = 0 gives t* = d/2 + ln[(1-π)/(π cm)] / d: a stricter gate when bugs are rare, a laxer one when a miss is expensive. The chart shows the numerical minimum agrees.

Simplifications. Equal-variance Gaussian scores (real tools have skewed, discrete scores and per-rule behaviour); findings are independent; every flagged finding is reviewed correctly; the cost of a miss is one number although it depends on severity and exploitability. Defensive triage teaching only. Checks: ROC area by integration vs closed form, the optimal threshold by numerical minimisation vs closed form, a Monte Carlo of 40,000 findings against Bayes, and a rank test with random pairs.