Freeze-drying: vial section (2D)

Ice sublimes under vacuum; the vapour is caught on a cold trap.

Switch to 3D

Presets

Playback

Parameters

Shelf, product and cold-trap temperature
Ice vapour pressure vs temperature
Ice and moisture remaining

Numerical checks (measured vs predicted)

The science

Freeze-drying removes water by sublimation: ice turns directly to vapour when the chamber pressure is below the vapour pressure of ice at the product temperature. The vapour pressure over ice follows the Murphy-Koop fit (about 12.8 Pa at -40 C and 611 Pa at 0 C). The shelf supplies heat; each vial sublimes at a rate set by the driving pressure difference and the resistance of the already dried layer, and the latent heat L_sub = 2.834 MJ/kg cools the product. If the product warms above its collapse temperature the cake loses structure.

What this 2D view adds

  • A cross-section of vials, shelf, duct and cold trap with the dried cake and ice front per vial.
  • The vapour-pressure curve with the chamber pressure and product temperature, plus temperatures and ice remaining over time.

Honest simplifications

Lumped chamber, simple resistance model, no radiation or edge-vial effects. It is educational and not suitable for pharmaceutical process validation. Same physics module as the 3D page.