A heat diode in the ground. A thermosyphon is a sealed pipe filled with a two-phase fluid (CO2 or ammonia). In winter, when the air is colder than the ground, the fluid evaporates at the buried end, rises, condenses in the finned top and runs back: heat leaves the ground. In summer the condenser is warmer than the liquid and nothing flows. The model treats it as a one-way conductance, q = G max(0, Tground - Tair) per metre of pipe, driven by Tair(d) = Tmean - A cos(2π(d - 15)/365).
Freezing soil. Around the pipe, radial heat conduction is solved on an enthalpy grid: frozen soil H = Cf(T - Tm), a narrow mushy zone that absorbs latent heat L = θ·334 MJ/m³ (ice content θ), and thawed soil above. Conduction between cells uses the exact logarithmic conductance k/ln(ci+1/ci), so the steady profile is exactly logarithmic. The frozen radius grows through winter and shrinks in summer; whether the frozen cylinder survives the year is what protects the foundation.
Checks. (1) the steady radial profile against T1 + (T2 - T1)ln(r/r0)/ln(R/r0); (2) the seasonal-wave damping depth d = √(2α/ω) in frozen ground; (3) energy balance over a year with latent heat; (4) the planar Stefan problem against the Neumann solution s = 2λ√(αt), λeλ²erf λ = Ste/√π.
Simplifications. Axisymmetric single pipe in an infinite cell with a fixed far-field temperature, no groundwater flow or moisture migration, constant thermal properties per phase, a lumped condenser with no wind or snow effect, no heat input from the building apart from the far-field temperature, unfrozen water content approximated by a 0.05 K mushy zone. Parameters are textbook values, not site data.