Load-path model
A uniform vertical area load q covers a simplified 7 × 11 roof grid. The 60 interior columns are modelled as grid nodes; the boundary nodes bear the rest.
Abay = (26.82 / 7) × (43.89 / 11) m²Ftotal = q × 26.82 × 43.89 kNFcolumn = q × Abay kNσ = Fcolumn / (π × (0.56 / 2)²) kPaFwalls = Ftotal − 60Fcolumn
Independent check: a second calculation divides each of the 77 bay loads into four equal nodal reactions and adds all reactions. The displayed check compares the computed central node with the closed-form column result.
Evidence levels
Documented: plan dimensions, 60 stone columns, 70 rounded domes, 7 chau-chala central vaults, 4 towers and arched façades.
Scholarly reconstruction: approximate elevations, bay spacing, arch geometry, roof profiles and conceptual building sequence.
Artistic interpretation: masonry patina, planting, load indicators and ground setting. The 0.56 m diameter and selected pressure are experiment assumptions, not surveyed data.
The model does not resolve masonry thrust, buckling, self-weight allocation, seismic forces or foundations. It is a tributary-area teaching model, not a structural assessment of the monument.
Educational reconstruction; details marked as reconstruction are interpretive.
Sources