WORLD HERITAGE RECONSTRUCTION / BAGERHAT

Shait Gumbad Mosque

Seventy-seven roof bays. Sixty interior columns. One remarkable system of brick, arches and gravity.

INTERACTIVE ARCHITECTURAL MODEL Preparing viewer
Southeast perspectiveSchematic view · not a measured survey
DRAG ORBIT · SCROLL ZOOM · RIGHT-DRAG PAN
Keyboard: ← → ↑ ↓ orbit · + / − zoom · 0 reset
01

Explore the structure

Reveal the construction logic beneath the roof.

0%
Complete roofOpen interior
Completed
FoundationsRoof and details
14:00
06:0018:00
02

Load-path experiment

Change a hypothetical effective roof load and see how a simplified force model responds.

3.0 kN/m²
1.0 kN/m²8.0 kN/m²
Total vertical load
4,736kN
q × roof footprint
Load / interior column
47.4kN
60% assigned to 60 columns
Mean column stress
0.30MPa
Assumed Ø 0.45 m
≡
Independent area check
77 bay sum: 4,736 kN · direct rectangle: 4,736 kN
0.00%
Brick and masonryStone columnsIllustrative load path
Science & history notesEquations, assumptions, evidence and sources

What is documented?

The Shait Gumbad (Sixty Dome) Mosque is part of UNESCO's Historic Mosque City of Bagerhat. Sources describe an approximately 49 m by 32 m plan, 60 interior supports, 77 roof bays including seven chauchala roofs, thick brick walls and four round corner turrets. Sources disagree slightly on external measurements; the geometry here follows 48.95 × 32.25 m.

Survey-based: footprint, grid counts, bay distribution, massing, entrance arrangement, brick and stone material families. Scholarly reconstruction: illustrative dome profiles, interior height, wall openings and roof load distribution. Artistic: individual brick weathering, surrounding trees, terrain and illumination.

What does the experiment solve?

The pedagogical load is a variable, not a measured historical roof mass. Total vertical force F = q × (L × W); the interior-column portion Fcolumns = αF, with illustrative fraction α = 0.60. Per-column mean Fc = αF/60. Average compressive stress σ = (Fc×1000)/(πd²/4), with assumed d = 0.45 m. These do not model vault thrust, contact, settlements or actual structural capacity.

The independent check accumulates loads over all 77 grid cells and compares that numerical total with the direct plan-area formula. A zero difference checks the arithmetic—not the historical load assumption.

Educational reconstruction; details marked as reconstruction are interpretive.

BAGERHAT / BANGLADESHArchitecture · Materials · Structural mechanics
Made with 🤖 ChatGPT · Three.js