FIELD LAB / CIVIL ENGINEERING / 001

The lockworks.
Water under control.

Operate a real-world-inspired navigation lock, balance hydraulic head, and guide a vessel between two elevations.

Initializing renderer·INTERACTIVE MODEL
Chamber level
2.50 m
Net flow
0.0 m³/s
Max gate load
1.17 MN
Ship speed
0.00 m/s
Drag orbit   Scroll zoom   Right-drag pan   Tap inspect a component

Preparing the lockworks

Initializing the graphics system and assembling the procedural model…

Civil infrastructure / Hydraulics / Digital exhibit

How a navigation lock lifts a vessel

A navigation lock is a water-filled chamber that allows boats to pass between waterways of different elevations. Rather than lifting the boat with a mechanical hoist, engineers adjust the chamber’s water volume. The vessel rises or falls through buoyancy as the water surface changes.

01 / Pressure drives flow

The culvert discharge is estimated using Q = CdA√(2g|Δh|), with the sign determined by the water-level difference. The model integrates net flow into the chamber, using a fixed surface area of 250 m².

02 / Gates resist hydrostatic load

The pressure on a vertical gate increases with depth. The model reports net gate load using F = ½ρgb(h₁² − h₂²). For operation, the gate heads must be nearly equal to avoid unsafe loads.

03 / Buoyancy makes the lift

The barge maintains an illustrative 1.3 m draft. Its vertical position follows the local water surface, while horizontal motion comes from a damped throttle-and-drag model with gate collision interlocks.

Knowledge base

Questions about navigation locks

1. Why are two gates needed in a navigation lock?

Two gates isolate a chamber from water bodies at different levels. With both gates closed, operators can add or remove water through culverts. After the chamber level matches one side, the corresponding gate can open and the boat can travel through. The gate on the opposite end remains closed.

2. How does the water enter the chamber?

Valves control submerged culverts that connect the chamber to the upper or lower reach. A pressure difference drives the movement: water normally enters from the upstream reach when filling, and flows toward the downstream reach when emptying.

3. Is a pump required to raise the boat?

No, not in a conventional gravity-fed navigation lock. Water flows from the higher reach into the chamber when a valve opens. This raises the surface and the floating boat. Pump-assisted or water-saving systems exist where water supply is constrained.

4. What prevents a gate from opening against a large head?

Real systems use operating rules, monitored water levels, and mechanical or automated interlocks. This simulation similarly blocks a gate-opening request until the chamber water level is within 0.04 m of the adjoining reach, both culvert valves are shut, and the opposite gate is closed.

5. What does the simulated flow rate represent?

The displayed flow is the signed net discharge in cubic metres per second, calculated from a simplified sharp-edged-orifice relation. Positive values fill the chamber; negative values drain it. The model neglects detailed culvert friction, localized losses, turbulence, and water hammer.

6. How is a vessel lifted without changing its draft?

For a floating vessel, buoyancy balances its weight. When the surrounding water rises, the vessel follows it while its displaced volume remains approximately constant. Here, a fixed draft represents a barge with unchanged cargo and displacement.

7. What are mitre gates?

Mitre gates use two hinged leaves that meet in the center. A pressure difference presses them together against their contact surfaces, creating a strong closure. Their hinged construction allows the leaves to swing back toward the chamber wall once the levels are equalized.

8. Why does filling slow down near the top level?

The driving head decreases as the chamber level approaches the upper reach. Orifice velocity scales with the square root of the head difference, so the discharge declines even if the valve remains fully open.

9. How is gate force calculated?

For water depth h on one side, the integrated hydrostatic load across a vertical gate of width b is ½ρgbh². The displayed net load is the absolute difference between the two sides. It is a total force estimate, not a gate-hinge torque or structural stress calculation.

10. Can this model be used to design a real lock?

No. This is an educational engineering visualization with simplified hydraulics, kinematic gate drives, and an illustrative vessel model. Real design requires site-specific geometry, transient flow analysis, vessel dynamics, structural calculations, fail-safe control systems, and applicable engineering standards.