World heritage reconstruction · Japan

Himeji Castle Main Keep

A measured, interactive interpretation of the five-roof timber keep, its stone platform and the central columns that anchor its frame.

Himeji · c. 1609Three-quarter viewHigh quality
Five roof tiers · timber lattice · stone platformDocumented proportions with interpretive details identified in the science panel.
Canvas2D fallback view
The science and historical record

Equations used

W = A × q · total illustrative vertical load.

R = W × s / 2 · equal reaction assigned to each of two central columns.

σ = R / (πd² / 4) · average axial stress using an idealised circular base section.

Default values: A = 500 m², q = 2.5 kN/m², s = 0.40, d = 0.95 m.

What is simplified

The calculation isolates two central supports and assumes equal sharing. It does not solve the complete timber lattice, joints, roof framing, eccentricity, bending, shear, moisture, settlement or earthquake response.

Documented: 31.5 m building height, 14.85 m stone base, two central columns, and column dimensions published by Himeji City. The Japan Tourism Agency independently describes the central columns and surrounding timber lattice.

Reconstructed: exact floor spacing, member sections, roof pitches, plan proportions and many joints. Artistic interpretation: surface wear, terrain, trees, lighting and weather.

Sources

  • Himeji City · Scale of Himeji Castle (https://www.city.himeji.lg.jp/castle/0000007746.html)
  • Japan Tourism Agency · Castle Craftsmanship: Wooden Framing (https://www.mlit.go.jp/tagengo-db/en/R1-00695.html)
  • Himeji City · History of Himeji Castle (https://www.city.himeji.lg.jp/castle/0000007750.html)
  • Japan Tourism Agency · Himeji Castle History (https://www.mlit.go.jp/tagengo-db/en/R1-00663.html)
  • UNESCO · Decision 17 COM XI (https://whc.unesco.org/en/decisions/3337/)

Educational reconstruction; details marked as reconstruction are interpretive.