Equations used
q = ½ρV² gives dynamic pressure. The height profile is V(z) = V₁₀(z/10)^α. Strip forces are summed to estimate total force and overturning moment.
The analytical force check integrates the same power-law pressure profile over the modelled facade. The engine result uses 24 horizontal strips.
Documented dimensions
- Keep height: 31.5 m above the stone base.
- Stone base: 14.85 m.
- Two central columns: about 24.5–24.6 m high; the city gives 0.95 m at the base and 0.42 m at the top.
- Six floors above ground, one basement and five roof tiers.
Reconstruction and simplification
The overall silhouette follows published descriptions and the city’s restoration drawing archive. Plan envelope, floor-by-floor widths, wall thicknesses, stone-block placement, roof details and landscape are scaled or interpretive.
The wind experiment assumes air density 1.225 kg/m³, drag coefficient 1.3 and power-law exponent 0.14. It omits turbulence, local shielding, openings, detailed roof pressure, structural stiffness and measured building mass.
Educational reconstruction; details marked as reconstruction are interpretive.
Sources
- UNESCO World Heritage Centre — Himeji-jo (https://whc.unesco.org/en/list/661/)
- Himeji City — Scale of Himeji Castle (https://www.city.himeji.lg.jp/castle/0000007746.html)
- Japan Tourism Agency — Castle Craftsmanship: Wooden Framing (https://www.mlit.go.jp/tagengo-db/en/R1-00695.html)
- Himeji City — The Main Keep and restoration drawings (https://www.city.himeji.lg.jp/castle/0000015570.html)
- Agency for Cultural Affairs — National Cultural Property Database (https://kunishitei.bunka.go.jp/bsys/maindetails/102/2264)
- Kajima — National Treasure Himeji Castle Main Keep (https://www.kajima.co.jp/english/tech/himeji_castle/index.html)