Select one of the numbered markers on the model to inspect a documented feature. Drag to orbit, scroll to zoom, and use Shift-drag or right-drag to pan.
The science and historical record
Principal principle. Thick earthen walls slow conductive heat transfer; high-level openings can assist warm-air exhaust. The calculations isolate those mechanisms and do not predict the actual indoor climate of the mosque.
Equations used
Assumptions and limits
- Effective conductivity 0.65 W/(m·K), discharge coefficient 0.62, opening area 0.025 m² per roof vessel and effective stack height 3.5 m are illustrative inputs, not measurements of this mosque.
- The heat-flow calculation is steady-state and one-dimensional. It omits solar absorption, moisture, thermal bridges, openings, transient heat storage and wind-driven ventilation.
- The ventilation equation uses an equivalent opening area and a single temperature difference. It is not a CFD model or a measured air-change rate.
- The independent check calculates the same wall transfer by two algebraically equivalent paths; it is a numerical consistency check, not an independent field measurement.
Documented, reconstructed and interpreted
- Documented: earthen brick and mud plaster; projecting palm-wood toron; raised platform; approximate prayer-hall dimensions; 90 pillars reported in a 10 × 9 arrangement; roof ventilation vessels; recurring community maintenance.
- Scholarly reconstruction: the scaled building envelope, simplified column spacing, wall thickness midpoint and the relative placement of some secondary forms.
- Artistic interpretation: surface colour variation, weathering, surrounding houses, trees, exact opening positions and lighting.
Educational reconstruction; details marked as reconstruction are interpretive.
Reference data loading…
Model period: 1906–1909 CE · Scale: 0.25 model metres per documented metre