How UV disinfects
254 nm light is absorbed by microbial DNA and blocks replication. The inactivation depends on the dose (fluence), the fluence rate integrated along each particle's path: D = ∫ E dt in mJ/cm2. Published dose-response tables (US EPA UV Disinfection Guidance Manual, 2006) give the log inactivation: for example 12 mJ/cm2 for 3-log Cryptosporidium, 7.7 for Giardia and 143 for adenovirus. The model interpolates those tables; the E. coli curve is a simple illustrative D10 of 3 mJ/cm2.
Fluence rate around a lamp
For a long lamp of arc length La and UV output P, the fluence rate at distance ρ from the axis is E = P exp(-α(ρ - r0)) / (2π ρ La) with the absorption coefficient α = -ln(UVT/100) / 1 cm (UVT = transmittance per cm). Several lamps simply add. The 1/ρ geometric term and the exponential Beer-Lambert term together make the water near the wall and between distant lamps receive much less dose.
Lagrangian dose
1500 particles are tracked through the 1.4 m vessel with a 1/7-power axial velocity profile and turbulent radial mixing (eddy diffusivity 0.067 u* R, u* = 0.061 U). Each particle accumulates its own dose. Because inactivation is a log-law, the reactor credit is LI = -log10( mean(10-f(Di)) ), always below f(mean dose): under-dosed particles cost more than over-dosed ones give. The reduction-equivalent dose (RED) is the dose that would give the same credit with perfect mixing.
Lamps, fouling and energy
UV output = electrical x 0.35 x 0.4 (sleeve, end effects, derating) x power setting x ageing (down to 75 % at 12 000 h) x sleeve transmission. Sleeve fouling grows with iron and hardness and with low UVT; wipers restore it. Electrical energy per order is EEO = Pel / (Q LI). Auto dimming lowers the power until the RED is 110 % of the requirement.
Honest simplifications
Infinite-line-source optics (no end effects or wall reflection, absorbed in the derating factor), a single dose-response curve per organism with no shoulder or tailing, no particle shading, no polychromatic spectrum, no hydraulics from inlet bends. Lamp ageing is accelerated 20 times for demonstration. Not a validated reactor design.