Steady electrical conduction in a homogeneous electrolyte: ∇·(σ∇φ) = 0, with copper electrodes held at fixed electrolyte potentials and insulating outer walls.
Current density: J = −σ∇φ. Local copper growth uses Faraday's law: dh/dt = η M |Jₙ| / (2 F ρ). Here M = 0.063546 kg/mol, F = 96485.33212 C/mol and ρ = 8960 kg/m³ are textbook copper constants.
Numerics: a fixed 1/60 s simulation update accumulates local deposition. A 2D finite-difference Laplace solver determines current, and face fluxes are integrated independently around the cathode and across the bath.
What is simplified: this is a primary-current-distribution model with constant conductivity. It neglects electrode kinetics, ion depletion, diffusion-limited growth, agitation, roughness evolution, and the voltage needed for electrochemical reactions. Electrodes remain fixed as the film grows.
What is illustrative or scaled: the bath geometry and applied electrolyte potential are illustrative; drifting ions are visual guides, not ion trajectories; the copper coating is visually enlarged so micrometre growth can be seen. The flat-plate comparison is a textbook limiting case, not an exact prediction for finite electrodes.
This exhibit is an independent educational model and is not affiliated with any equipment manufacturer.