THE SCIENCE CABINET AN INTERACTIVE FIELD LAB
EXPERIMENT 02 / CHEMISTRYGCSE FOUNDATION
WATER QUALITY SERIES NOTEBOOK Nº 014

The Lather Ledger

How much soap does hard water steal? Add drops, shake the flask, wait for the lather and find out what is dissolved in your sample.

ANALYSECa²⁺ + Mg²⁺BY SOAP TEST
02 THE LABORATORY BENCH

Watch the reaction

READY TO TEST
Interactive soap pipette and water test flask The flask shows a water sample, insoluble soap scum and foam. Dispense using the pipette plunger and shake by dragging the flask sideways. BENCH / FIG. A SOAP REAGENT • 20 mmol/L 50.0 mL SAMPLE TOWN TAP 01020 mL PIPETTE DRAG PLUNGER ↓ SHAKE ↔ THEN WAIT 15 s WATER + SOAP → SCUM + LATHER
0 s since shake0.00 mL soap
Begin by dispensing soap. Shake the flask and observe it after 15 seconds.
04 DATA ANALYSIS

A line from your measurements

Every dot is a real 15-second reading. Find the dose where foam stops collapsing.

Your observations Simplified model
Experimental rule: keep the sample volume (50.0 mL), soap strength (20 mmol/L) and observation delay (15 s) the same.Soap blank: 1.00 mL
05 PRACTICE WORKBOOK

Put your results to work

Seven freshly generated questions from your own practice set.

0 / 7COMPLETED
BEGINNERQUESTION 01 / 07

Loading question…

Choose or enter an answer, then check it.

LAB NOTES / THE KEY REACTION

One Ca²⁺ or Mg²⁺ ion binds two negative soap ions, creating insoluble scum.

M²⁺ + 2 RCOO⁻ → M(RCOO)₂ ↓
06 / WHAT YOU WILL LEARN

Three things to take away.

  1. Explain why Ca²⁺ and Mg²⁺ cause soap scum and reduce lather.
  2. Make a fair water-hardness comparison using an identical soap test.
  3. Calculate and interpret hardness in mg/L as CaCO₃ from an endpoint.
THE EQUATIONS

From drops to data.

Soap consumed = 2 × moles of hardness ions
n = c × V   (V in litres)
Hardness = 100.0869 × mmol of ions / L

The 1.00 mL soap blank is a deliberately fixed lather threshold at these settings—not a universal law.

IN THE REAL WORLD

Why this matters.

Hard water uses more soap and can cause deposits in pipes and kettles. Boiling helps remove temporary carbonate hardness; ion exchange can soften both kinds.

Simplifications: one divalent-ion equivalent per CaCO₃ unit; full idealised soap precipitation; an empirical foam threshold. Boiling removes 90% of temporary hardness here; ion exchange removes 99% of both. Actual tests depend on soap formulation, shaking, temperature and other dissolved substances. This is an educational model, not a certified water test.

Made with 🤖 ChatGPT