The Nernst equation
Identical electrode reactions cancel their standard potentials. For an ideal dilute solution, concentration approximates thermodynamic activity. If the right side is more concentrated, E(right − left) is positive.
Two identical metals. Two different concentrations. One measurable electric potential. Build the cell, change its chemistry and discover why electrons move.
Five or more fresh, verifiable questions each round. Every question includes an experimental setup you can load on the bench.
Every question is generated from a physically valid concentration cell, not a fixed answer bank. Compare your prediction with the live instrument.
Use the supplied temperature and ion concentrations.
Drag the red and black leads to check polarity.
Close the circuit or add a measured drop to test your claim.
Identical electrode reactions cancel their standard potentials. For an ideal dilute solution, concentration approximates thermodynamic activity. If the right side is more concentrated, E(right − left) is positive.
When the circuit closes, the dilute half-cell oxidises metal and becomes richer in metal ions. The concentrated side plates metal and becomes poorer. A salt bridge maintains electrical neutrality.
With the switch open, an ideal voltmeter reads the open-circuit EMF. Under load, the terminal voltage is smaller because a finite internal resistance causes an ohmic voltage drop.
Well-mixed half-cells · constant temperature per experiment · identical metal electrodes · constant electrolyte volumes except deliberate pipetting · perfect salt-bridge ion compensation · ideal ionic activities (a ≈ c / 1 mol L⁻¹) · fixed lumped internal resistance · no electrode polarisation or concentration boundary layers. The 0.50 M stock solution is illustrative; real high-ionic-strength cells require activity corrections. Ion dots are concentration indicators, not a molecular-scale depiction. Time is accelerated; charge and moles still follow Faraday’s law.
Real-world connections: ion-selective electrodes, electrochemical sensors, corrosion, cell design and battery diagnostics.