The Claus process turns H2S from gas treating into sulfur. One third of the H2S is burned to SO2 in a furnace, then the rest reacts with it over alumina catalyst. Sulfur is condensed after every stage, which pulls the equilibrium forward.
Stage extent: ξi = η(Ti) · min(nH2S/2, nSO2), with η(T) = 1 / (1 + exp((T − 270)/40)). Each reaction event makes 3 S atoms. Colder reactors favour sulfur, but must stay above the sulfur dew point (about 180 °C) so it does not condense on the catalyst.
Honest simplifications. η(T) is an illustrative fitted curve (it falls with temperature, as the exothermic equilibrium does), not tabulated thermodynamic data. The furnace converts a fixed 60 % of the limiting reagent. Inert CO2 and N2 only dilute. There is no COS/CS2 formation or hydrolysis, no hydrocarbons, no ammonia, no tail-gas treating unit, and sulfur is modelled as total S atoms. Educational process chemistry only.