MEMBRANE / OBJECT STUDY
Spiral-wound element · 3D inspection
Reverse osmosis · Assembly & flow

Inside the membrane element

Inspect the pressure vessel, wound membrane envelopes, feed spacer and permeate collection tube. The animated flow is linked to the same film-theory model as the 2D laboratory.

Orbit to inspect. Switch camera presets to reveal the membrane layers and the permeate path.
Assembly / interactive cutaway
Spiral-wound membrane element
INITIALISING SCENE
01 / Pressure vessel assembly
Permeate / waterSalt / concentrateMembrane active layerFeed spacer
Water flux
21.46 LMH
Salt rejection
99.21 %
Permeate salinity
0.28 g/L
Surface / bulk ratio
1.43 ×
The science · model and numerical check

Jᵥ = A(T)[ΔP − β(T)(Cₘ − Cₚ)]JᵥCₚ = B(Cₘ − Cₚ)Cₘ = Cₚ + (Cᵦ − Cₚ)e^(Jᵥ/k)

Independent salt-flux and water-flux residuals are calculated from the shared model. The visual geometry is schematic and not to scale. Assumptions: steady single-element slice, ideal NaCl osmotic pressure, simplified temperature correction, no axial depletion, pressure drop or fouling.

Made with 🤖 ChatGPT · Three.js