The science — constant-pressure cake filtration
Textbook A surface element filters only while submerged. For constant pressure, the cumulative filtrate volume per unit area is governed by the medium resistance and the growing cake resistance.
t = (μ / ΔP) [Rₘ v + (α c / 2) v²]Here v is filtrate volume per filter area (m), μ is viscosity (Pa·s), ΔP is vacuum pressure difference (Pa), Rₘ is medium resistance (m⁻¹), α is specific cake resistance (m/kg), and c is dry solids per filtrate volume (kg/m³).
Q = v A f N · δ = c v / ρcakeThe drum area is A = 2πRL, f is the submerged circumference fraction, N is revolutions per second, and δ is the estimated dry cake thickness. The bisection solution is checked against an independent closed-form quadratic root.
Simplifications: uniform pressure difference, uniform slurry concentration, constant cake resistance coefficient, incompressible liquid, and a uniform cake bulk density. Wash, drying, cloth blinding, gas breakthrough, and compressible-cake effects are not modelled. Throughput is an idealised cycle-average estimate.
Illustrative The selected dimensions and material properties are illustrative engineering values, not a design guarantee.