Manganese Dioxide Calcination: Thermobalance Kinetics, Oxygen Pressure and Kissinger Analysis

MnO2 loses oxygen in two steps as the furnace heats: Arrhenius kinetics, an equilibrium oxygen pressure that the sweep gas controls, and a TGA curve you can analyse.

Switch to 2D

Presets

Playback

Atmosphere

Parameters

Camera

Layers

Quality

Model check

The science

What you see. A vertical thermobalance: a small crucible of manganese dioxide hangs from a microbalance into a tube furnace while the furnace follows a heating programme and a sweep gas (nitrogen, air or oxygen) flows through the tube. The balance records the mass (TGA), the heat flow shows the endothermic steps. The crucible colour follows the phases: black MnO2, brown Mn2O3, dark red-brown Mn3O4. Click a gas cylinder to change the atmosphere.

The two steps. 4 MnO2 → 2 Mn2O3 + O2 (near 500 to 600 °C) and 6 Mn2O3 → 4 Mn3O4 + O2 (near 900 to 1000 °C). The mass left after the steps follows from formula masses: 90.8 % after the first, 87.7 % after the second. The reaction enthalpies come from formation enthalpies (−520.0, −959.0 and −1384.0 kJ/mol): +162 and +218 kJ per reaction as written.

Kinetics. Each step is a contracting sphere with a thermodynamic driving force: dα/dt = k(T) (1 − pO2/peq(T)) (1 − α)2/3, k = A e−Ea/RT / (1 + d/120 µm) and peq = exp[(ΔH/R)(1/Tref − 1/T)]. This gives the Le Chatelier effect: in nitrogen the oxygen pressure is tiny so decomposition starts at a lower temperature, in pure oxygen it starts later. Larger particles and faster heating shift the peaks to higher temperature.

The gas in the tube. The oxygen released does not vanish: the tube is a stirred volume with dy/dt = [Qin(yin − y) + ṁ(1 − y)]/N. A large sample in a weak nitrogen flow raises pO2 in the tube and slows the reaction. The volume is read from the Blender mesh of the tube.

Honest simplifications. The pre-exponential factors, activation energies (150 and 250 kJ/mol), reference temperatures for peq and the particle-size factor are illustrative values chosen to place the steps in the textbook temperature ranges, not fitted to a measured sample. The tube is one well-mixed volume at a single average temperature; the sample is a single bed of identical spheres without heat or mass transfer limits; buoyancy and crucible effects on the balance are ignored; real MnO2 varies (hydrated, non-stoichiometric) and can pass through intermediate phases.

Checks. (1) The mass lost computed from formula masses equals the mass of oxygen counted from the reaction coefficients, and the final mass is the Mn3O4 stoichiometry. (2) A Kissinger plot of simulated peak temperatures at five heating rates recovers the 150 kJ/mol input. (3) A pulse of oxygen through the mesh-sized tube closes the balance out − in + stored, and the 3 s update equals a 0.05 s Runge–Kutta integration. (4) The tube radius and length are recovered from the GLB triangles and the stirred-tank steady state matches its formula.

Loading model...
Loading Blender model...
Sample mass (TGA) and reaction rate against temperature
Phase composition against temperature
Oxygen pressure in the tube against the equilibrium pressures
Made with 🟠 Blender · Three.js