Cell resistance
R = d/(κA) + 0.8 Ω
Conductivity κ = 6c S/m is a teaching approximation; c is in mol/L. The constant 0.8 Ω represents supply and contact resistance.
An electroplating bench you can rearrange. Move electrodes through copper sulphate, reverse the leads and discover how every coulomb changes the metal.
Press Run experiment to begin recording current and copper mass over time.
Find how much charge crosses the bath.
Run an experiment, change the conditions and pin each result for comparison. All data stays in this browser session.
| RUN | GAP | CURRENT | CHARGE | COPPER |
|---|---|---|---|---|
| No trials pinned yet. Your first measurement is waiting. | ||||
Ideal mass balance: the mass lost at the copper anode equals the mass gained at the cathode, even after swapping polarity.
Electroplating protects components, gives jewellery a metallic finish and coats engineering parts. This model isolates the core charge and resistance relationships.
R = d/(κA) + 0.8 Ω
Conductivity κ = 6c S/m is a teaching approximation; c is in mol/L. The constant 0.8 Ω represents supply and contact resistance.
Cathode: Cu²⁺ + 2e⁻ → Cu
Anode: Cu → Cu²⁺ + 2e⁻
The copper anode replenishes the ions deposited at the cathode.
Q = It; m = QM/(2F)
Two moles of electrons are required per mole of copper. F = 96,485.33212 C/mol; M(Cu) = 63.546 g/mol.
Important model limits: The bath uses a uniform facing area and simple Ohmic resistance; conductivity proportional to concentration is only a simplified classroom relation, not a full copper-sulphate calibration. Assume 100% current efficiency, constant temperature, no electrode polarisation, concentration gradients, impurities or gas evolution. The animated ions are schematic markers, not a particle-level simulation; coating widths are visually exaggerated. This is not a device design calculator.