THE COPPER
CURRENT LAB
INTERACTIVE CHEMISTRYGCSE FOUNDATION
GALLERY 04 / THE ELECTROCHEMISTRY HALL

Make copper move.

Build an electrical circuit. Pull copper atoms from one electrode and plate them onto another — measuring every coulomb along the way.

EXPERIMENT NO.026REDOX / MATERIALS
01Identify the anode and cathode during electrolysis.
02Explain how charge transfers copper between electrodes.
03Investigate how gap, voltage and immersion affect current.

01 / INTERACTIVE APPARATUS

The plating bench

● Circuit closed

Drag the copper object to change its distance and immersion. Drag a + or − lead onto either terminal, or use the wiring buttons.

BATTERY / DC SOURCECOPPER SULFATE / CuSO₄(aq) 8.0 VDC SUPPLY+− +Positive cable: select and click an electrode terminal −Negative cable: select and click an electrode terminal Cu / DONOR OBJECTCopper object, draggable. Arrow left/right adjusts gap, up/down immersion Source copper electrode terminal Copper object electrode terminal SOURCEOBJECT ↔ IDEALISED ION MOTION 8.0 cm
Cu²⁺ ions / illustrative pathsCopper moving → object
WIRE THE CIRCUIT Drag leads or choose a connection

Power connected. Start the clock to transfer copper.

Current0.00 AR = 0.0 Ω
Charge passed0 C00:00 elapsed
Object copper change+0.0 mgDonor: 80.000 g
Surface change+0.0 µmArea: 26.2 cm²

02 / LIVE DATA

What does the charge do?

AUTO-SCALING
Net object mass (mg) Current (A)
Time (seconds) → 0–60 s

05 / PUT YOUR KNOWLEDGE TO WORK

The copper trials

0 / 8 complete
CHALLENGE 1 OF 8BEGINNER

Loading a new question…

06 / SCIENTIST'S NOTEBOOK

Compare your runs

Record your measured result, change the setup, and see how your copper transfer compares.

RunCurrentChargeObject Δ
No results yet. Record your first run.

FROM THE LAB TO REAL LIFE

Why plate a metal?

Electroplating can protect jewellery, decorate fittings and prepare electronic components. Manufacturers control current, chemistry and surface preparation to improve the finish.

Our simplified assumptions

Both electrodes are copper; 100% of electrical charge transfers Cu²⁺; the bath is well mixed and at constant temperature; copper-ion concentration stays approximately constant because the anode dissolves. Conductivity follows a teaching approximation, resistance is uniform, and deposition is evenly spread across the dipped facing surface. The 0.65 V polarisation drop is illustrative. There are no competing reactions, bubbles, depletion layers or edge effects. Ion positions and coating width are not drawn to scale.

Made with 🤖 ChatGPT