Each batch converts substrate to product following first-order kinetics with an effective rate constant that falls as the catalyst ages:
X = 1 − exp(−k_eff · t)
k_eff = k0 · a (a = catalyst activity, 0–1)
Activity decays differently by deactivation mechanism:
- Leaching — active-site atoms dissolve into solution each cycle; a(n) = a(n−1)·(1 − d). Particles visibly vanish from the bed.
- Sintering — small particles fuse into fewer, larger ones. Total metal mass is conserved but surface area drops as area ∝ N2/3 for fixed volume, so activity falls even though nothing is lost.
- Poisoning — impurities irreversibly occupy active sites; coverage θ builds up each cycle (θ ← θ + d·(1−θ)) and a = 1 − θ. Geometry is unchanged, only surface color darkens.
Green-chemistry waste accounting (E-factor = mass waste ⁄ mass product) treats a spent catalyst charge as waste the moment it is discarded. Reusing one charge over many cycles amortizes that fixed cost over more product and drives the cumulative E-factor down; frequent replacement (fast decay, aggressive settings) drives it back up — exactly the trade-off industrial catalyst design has to solve.