loading...
running...
The science
A titration adds a solution of known concentration (the titrant, in the burette) to a measured volume of analyte (in the flask) until the reaction is stoichiometrically complete. The pH is not read off a formula for one regime: this page solves the exact charge balance at every volume with a bisection solver, so buffer regions, equivalence points and the flat tails all come from one equation.
Species of a polyprotic acid
alpha_i = (K1...Ki · h^(n-i)) / sum_j (K1...Kj · h^(n-j)), h = 10^(-pH)
alpha_i is the fraction of the analyte that has lost i protons. The distribution graph plots all of them against pH.
Charge balance (solved for h)
[H+] + [Na+] = [OH-] + C · ∑ i·alpha_i (acid titrated with NaOH)
[H+] + C · ∑ (n-i)·alpha_i = [OH-] + [Cl-] (base titrated with HCl)
C = Ca Va/(Va+Vb) and [Na+] = Cb Vb/(Va+Vb) are the diluted concentrations; Kw comes from a temperature fit pKw(T) = 4470.99/T - 6.0875 + 0.01706 T (T in kelvin), which gives 13.99 at 25 C.
Equivalence and the end point
V_eq,k = k · Ca Va / Cb pH at V_eq = ½(pKw + pKa + log C_salt) (weak acid, strong base)
The equivalence point is where moles of titrant equal moles of analyte, the steepest point of the curve (maximum |dpH/dV|). The end point is where the indicator visibly changes, at pH = pK_In. The error table shows how far each indicator misses the equivalence volume for the current system.
Buffer regions and Henderson-Hasselbalch
pH = pKa + log([A-]/[HA]) → pH = pKa at V = V_eq/2
Between about 10 % and 90 % titrated a weak acid and its conjugate base form a buffer: the curve is flat because adding base only changes the ratio [A-]/[HA]. The buffer capacity is largest at the half-equivalence point.
Indicators
fraction in base form = 1 / (1 + 10^(pK_In - pH))
The solution colour is the blend of the acid and base colours weighted by that fraction. The visible change spans roughly pK_In +/- 1. The "unmixed" colour near the burette tip is computed the same way from the local, not yet mixed, concentration, which is why a faint pink flash that disappears with stirring warns you that you are close to the phenolphthalein end point.
Honest simplifications
- Activities are ignored: concentrations replace activities, so the pH is a few hundredths off at 0.1-0.5 M.
- pKa values are held constant with temperature; only Kw changes with the temperature slider.
- CO2 absorption from air and carbonic acid outgassing are not modelled; the carbonic acid preset treats H2CO3 as a stable diprotic acid.
- Indicator colours are artistic blends of the real acid and base colours; the indicator itself is assumed not to consume titrant.
- Drop size is fixed at 0.05 mL; the "unmixed plume" amplifies a drop by a fixed factor for visibility.
Independent checks in this page
The panel re-derives the initial pH from a closed-form quadratic, compares the steepest point of the numerical curve with Ca Va/Cb, tests the Henderson-Hasselbalch half-equivalence point and the salt-hydrolysis formula, verifies the charge-balance residual and that the species fractions sum to 1.
3D models and baked PBR textures were made in Blender; Three.js r160 animates the stopcock, drops, liquid level and colours from the shared titration model.