The science
What is modelled
A six-floor traction elevator (floor height 3.6 m, 18 m of travel): a 1100 kg cab, a counterweight on the other side of the traction sheave, steel ropes, an optional compensation chain and a gearless motor. You pick a floor; the controller moves the cab along a jerk-limited S-curve and the model works out the motor force, the power (negative when the machine is braking and could return energy to the grid), the rope tensions and whether the ropes would slip on the sheave.
Equations
- Motion: seven phases with jerk
[+J, 0, −J, 0, −J, 0, +J]. The peak speed isvmaxon long trips; on short trips it is found fromd = vp (2Tj + Ta + Tc),Tj = ap/J,ap = min(amax, √(vp J)). - One rope joins the cab (height
cb) and the counterweight (wb = C − cb), so when the cab rises the counterweight falls by the same amount. - Static pull against lifting the cab:
G = g [ mcab + Q − mcw + ρ (lc − lw) + ρch (cb − wb) ], wherelcandlware the rope lengths on each side and ρ = 1.5 kg/m per side. - Inverse dynamics:
Fmotor = Meff a + G + f0 sgn(v) + b vwithMeff = mcab + Q + mcw + mrope + mchain + Jrot/R². Mechanical power isFmotor v; electrical power divides by 0.92 when motoring and multiplies by 0.92 when braking. - Rope tensions:
Tcab = Mcs(g + a),Tcw = Mws(g − a). The ropes hold whileThigh/Tlow ≤ eμθ(Euler-Eytelwein capstan law, wrap θ = π). - Counterweight balance:
mcw = mcab + β Qrated, β usually 0.4 to 0.5, so a cab with 45 % of its rated load hangs in balance and the motor only has to overcome friction and acceleration.
Checks run in the page
- The seven-phase profile for an 18 m trip, integrated with Simpson steps, covers exactly 18 m and ends at rest, matching the closed form
vp(2Tj + Ta + Tc). - Energy ledger: the motor work found by integrating
F v dtequals the change of potential energy of cab + counterweight + rope + chain plus the guide friction work (with and without the chain). - The load at which the ropes begin to slip, found by bisection on the tension ratio, equals the closed form
Mcs = eμθ Mws (g − a)/(g + a). - Without compensation the static pull changes by
2 ρ g Hover the travel; with the chain it is constant and equal to the closed-form value.
Honest simplifications
- The motor is an ideal force source that follows the reference profile; no drive-control loop, current limit, rope stretch or cab sway is simulated. Rope stretch would add a bounce of a few hertz in a real machine.
- When the tension ratio exceeds the limit the page only reports the slip; it does not simulate the cab creeping. Real elevators also have a safety gear, an overspeed governor and an emergency brake, which are not modelled.
- Rope and chain mass per metre, the 80 N + 40 N s/m guide friction, the 92 % drive efficiency and the 18 kg m² rotor inertia are typical illustrative values, not those of a specific product. Ride-quality limits (about 1 m/s² and 1.3 m/s³) are rules of thumb.
- Passengers are drawn from the load (one figure per 75 kg) but are not simulated individually.
What to try
- Select "Empty cab goes up": the motor power turns negative because the heavier counterweight is falling. Compare with "Full cab goes up".
- Switch on the compensation chain and watch graph 2 and the static unbalance reading: the position-dependent rope term disappears.
- "Poor grooves" lowers μ until graph 3 shows the loaded accelerating cab above the red slip line.
- Raise the load past 1000 kg: the cab refuses to leave the landing.