loading...
running...
How to use
Pick a preset or build your own frame, choose which column to remove (the sliders, or click a column in the view), then press Collapse. The structure is analysed stage by stage: member colour shows utilisation, red dots are plastic hinges, and parts that lose their support fall. Compare the presets: a robust frame forms hinges and arrests, a light frame buckles progressively, timber snaps without warning. Space pauses, R resets.
Things to try. (1) Remove an interior ground column in the default frame and see the neighbouring columns overload. (2) Set the amplification Ω to 1.0 and then 2.0: how much does the sudden loss matter? (3) Raise the debris energy transfer and watch an arrested collapse turn into a pancake. (4) Compare 3 and 10 storeys with the same members. (5) Remove a column near the roof instead of the ground.
The science
This is a progressive-collapse (alternate load path) study of a multi-storey frame: take one column away and ask whether the rest of the structure can carry its load by another route, or whether the failure spreads. The model is a real plane-frame finite-element analysis, not a canned animation.
1. Frame analysis. Every beam and column is an Euler-Bernoulli beam-column with axial and bending stiffness. The direct stiffness method assembles K d = F from element matrices (EA/L, 12EI/L³, 6EI/L², 4EI/L, 2EI/L) with rigid joints and fixed bases, and solves it with a banded Cholesky factorisation. Floor beams carry a uniform load w = q · s (floor pressure times the tributary width) plus self-weight; wind adds a lateral load at each floor.
2. Plastic hinges. A beam is elastic-perfectly plastic: when an end moment reaches the plastic moment M_p = f_y Z_p (steel), M_p = f_b b d²/6 (timber, brittle) a hinge is inserted (the rotation is released and the moment is held at M_p) and the structure is re-solved. This is how a beam fixed at both ends reaches its collapse load w_u = 16 M_p / L² after two end hinges and a mid-span hinge, one of the numerical checks below. Timber has no plastic plateau, so a member is lost the moment its strength is reached.
3. Columns. Compression capacity follows the European column curve: N_cr = π²EI/L², λ = √(N_y/N_cr), N_cap = χ N_y with χ = 1/(Φ + √(Φ² − λ²)), Φ = 0.5(1 + 0.34(λ − 0.2) + λ²). A column fails when N/N_cap + M/M_p > 1 (utilisation above 1, shown as colour: green low, red near the limit, magenta over it).
4. Sudden loss and dynamics. Removing a member is a sudden event. The design standards (UFC 4-023-03, GSA) treat the dynamic effect with an amplification factor on the loads of the bays next to the loss; here it is the slider Ω (2.0 would be a perfectly sudden, undamped elastic response; real structures often see 1.2 to 1.7). Each new failure starts another stage, 0.25 s apart.
5. Falling parts and impact. A part of the frame that loses its connection to the ground is a free-falling rigid body (h = ½ g t²). When it lands on an intact floor, the floor receives its weight with an impact factor DAF = 1 + √(1 + 2 η h / δ_st), δ_st = w L&sup4; / (384 E I) where η is the fraction of the impact energy that reaches the beam (the rest is spent crushing debris, slabs and cladding). This is the mechanism behind pancake collapse: the floor below is asked to stop a mass that has fallen one storey.
6. The verdict. EN 1991-1-7 asks that local damage does not exceed about 15 % of the floor area (or 100 m²) in each of two adjacent storeys. The readout computes the worst such pair from the beams actually lost.
Honest simplifications. Plane frames only, no 3D slab (membrane or catenary) action, no connection fracture, no P-delta effects, no lateral spreading of debris, no fire. Joints are assumed stronger than the members. Deflections are exaggerated by the slider to be visible, and the animation of a collapsing part is a rigid fall, not a fracture simulation. In the 3D view each frame carries its own strip of slab and cladding and the frames are assumed to act independently. This is an educational model of inanimate structures, not a design or assessment tool.