m.MYSIMULATOR.UK INTERACTIVE FIELD ATLAS • BIOLOGY SERIES EXPERIMENT LIVE № XB–01
THE LIVING HYDRAULIC SYSTEM / FIELD NOTE 01

Xylem Breakpoint.

How much drought can a plant withstand before the water highways inside its stem break?

A-LEVEL BIOLOGY VIRTUAL SCIENTIFIC INVESTIGATION SIMULATED STEM SECTION
YOU WILL LEARN
01Explain how tension causes xylem cavitation
02Calculate conductivity, flow and percentage loss
03Compare drought-resilience curves and P₅₀
01 / SPECIMEN OBSERVATORY

Inside the water column

Explore a stem cross-section. Tap or drag across a conduit to inspect its air-entry threshold. Amber bubbles mean lost conductivity.

XX′ XYLEMCONDUITS STEM SECTION SCHEMATIC · NOT TO SCALE
WATER FILLEDAIR BLOCKEDSELECTED
◎
INSPECTED CONDUIT 01 / 55Water conductingDiameter 42 μm · air-entry threshold −2.40 MPa
02 / HYDRAULIC CHAMBER

Apply drought pressure

XYLEM WATER POTENTIAL · Ψ
−0.10MPa

More negative = greater tension on the water column

−0.1−2.8−5.5 MPa
LIVE HYDRAULIC MEASUREMENTSΔΨ TEST = 0.20 MPa
CONDUCTIVITY LOST0.0%
REMAINING FLOW3.50mL/min
CONDUCTANCE17.50mL/min/MPa
AIR-FILLED VESSELS0/ 55
◈

Embolism has memory. Lowering tension does not automatically refill gas-filled conduits. Use Flush / reset for a new specimen.

03 / VULNERABILITY CURVE

Where does transport fail?

Explore how pressure changes the predicted conductivity loss. The live reading remembers all earlier drying, even when the pressure is released.

MODEL: NEW SPECIMENLIVE READINGNOTEBOOK SAMPLES
EXPERIMENT NOTEBOOK

No measurements recorded yet.

Drag the plunger or the curve, then record your first observation.
FIELD GUIDE / 04

The science inside

01 WATER UNDER TENSION

Transpiration pulls water upward through xylem. As soil dries, the water potential of the sap becomes more negative. Under strong tension, air can enter a vessel and break its continuous water column: cavitation.

HYDRAULIC FLOWQ = K × ΔΨmL min⁻¹ = (mL min⁻¹ MPa⁻¹) × MPa
02 NOT ALL VESSELS ARE EQUAL

For ideal laminar water flow through equal-length circular tubes, conductance ∝ radius⁴. The model gives each of 55 conduits its own radius and air-entry pressure.

PERCENTAGE LOSS OF CONDUCTIVITYPLC = 100 × (1 − K / K₀)Embolised conduits contribute zero flow.
03 THE BREAKPOINT

P₅₀ is the water potential at which the fitted, idealised vulnerability curve predicts 50% hydraulic loss. More negative P₅₀ means greater resistance in this experiment.

CURRENT P₅₀ / −2.65 MPa
VULNERABLE MORE RESISTANT
BEYOND THE LAB

Plant hydraulics research helps scientists investigate drought damage in forests, compare crop stress responses and understand why water transport can fail during heatwaves.

Experimental assumptions +

These are fictional specimens, not measured species datasets. Vessel radii and entry pressures are fixed. Each conduit follows ideal steady laminar flow and has the same length and viscosity; total conductance adds in parallel. A vessel stops conducting below its assigned threshold and remains air-filled until a laboratory flush. This demonstration does not model soil–root resistance, stomatal regulation, leaf capacitance, or natural embolism repair. The 0.20 MPa test pressure is a separate controlled flow measurement, not the displayed xylem tension.

05 / INSTRUMENT CHALLENGES

Put your observations to the test.

Ten newly generated questions combining calculations, scientific reasoning, and real manipulation of this laboratory.

0/10COMPLETED
0%
CHALLENGE GENERATOR
01 / NUMERICAL CALCULATIONQUESTION 1 OF 10

Hydraulic test flow

Made with 🤖 ChatGPT