Bee circulation without blood vessels (3D)

Pulsing dorsal vessel, ostia, accessory pumps and the open body cavity in a cutaway Blender bee.

Switch to 2D

Presets

Playback

Heart and vessel

View

Camera

Layers

Quality

Model check

The science

What you see

A Blender-modelled worker bee with a translucent shell. The red tube along the back is the dorsal vessel: five heart chambers that contract in a wave from the tail, then the thin aorta that opens in the head. Pale yellow dots are hemolymph tracers: inside the vessel they follow the parabolic Poiseuille profile, outside it they drift through the open body cavity, take a detour through a wing or a leg when the cyan accessory pumps are on, and re-enter the heart through the white ostia. The shell opacity slider lets you look through the thorax.

What is modelled

A honey bee has no arteries or veins. A tube along the back, the dorsal vessel, has a pulsing rear part (the heart, five chambers with slit-like inlet valves called ostia) and a thin front part (the aorta) that ends in the head. Each beat pushes hemolymph forward and out into the open body cavity, the hemocoel. From there it drifts back through the body and re-enters the heart through the ostia when the chambers relax. Small accessory pulsatile organs at the wing bases and legs help move fluid into those appendages.

Equations

  • Flow in the aorta (Hagen-Poiseuille): Q = Δp π R4 / (8 μ L), with a parabolic velocity profile u(r) = 2 v (1 - r2/R2), v = Q / (π R2). The viscous time R2ρ/μ is about 2 ms against a 120 ms beat, so each instant of the beat is a steady pipe flow.
  • One beat: the pressure pulse is a half-sine of duration Ts = 0.12 s, so Q(t) = Qpeak sin(π t / Ts), stroke volume SV = 2 Qpeak Ts / π and mean flow Q̄ = SV f. Mean flow grows with heart rate and falls with viscosity, as on the 3D page.
  • Dimensionless numbers: Reynolds Re = ρ vpeak 2R / μ (about 2: laminar) and Womersley Wo = R √(2π f ρ / μ) (about 0.1: quasi-steady).
  • Circulation time: by Little's law the mean time for a parcel to go round the whole circuit is Vtotal / Q̄.

Checks run in the page

  • A finite-difference solution of the unsteady pipe equation reproduces the Hagen-Poiseuille centre-line speed.
  • The same solver shows centre-line speed growing as R2 (flow as R4).
  • Tracers on the parabolic profile move on average by SV / (πR2) in one beat.
  • Simulated tracer circulation time agrees with Vtotal / mean flow.

Honest simplifications

  • Dimensions and pressures are representative orders of magnitude for a worker bee (vessel radius tens of micrometres, speeds of millimetres per second, hemolymph volume 10 to 20 microlitres), not measurements of one animal. The peak pulse pressure is a tunable input here.
  • The heart is treated as the same pipe as the aorta, a drawing convenience; its real chambers are wider and slower. The aorta length for the pressure drop is 3 mm.
  • The return flow through the hemocoel is a random-residence model (exponential waiting time with mean V / Q), shown with a time-lapse factor so that you can see a circuit in seconds. Real hemolymph also carries immune cells and is moved by breathing and body movements, which are not modelled.
  • Wing and leg pulsatile organs are represented as a fixed 12 % and 8 % share of the mean flow reaching the appendages (illustrative constants).

Real application

Because there are no closed vessels, a substance that enters the hemolymph is carried through the whole body within minutes. This is why the wall-free circulation matters when thinking about how toxins or pathogens spread inside a bee.

What to try

  • "Cold morning" doubles viscosity: mean flow halves and circulation time doubles.
  • Widen the aorta from 60 to 85 micrometres: flow rises by about four times (R4).
  • Switch the pulsatile organs off and see the appendage flow drop to zero.
Loading model...
Loading Blender model...
Flow during two heartbeats (dot = now)
Velocity profile across the aorta
Mean flow against heart rate
Made with 🟠 Blender · Three.js