The pacemaker is the Forger–Jewett–Kronauer (1999) van der Pol-type limit-cycle oscillator driven through Kronauer's light-transduction "Process L", with the constants of St Hilaire et al. (2007):
dx/dt = (π/12) [ xc + μ(x/3 + 4x³/3 − 256x^7/105) + B ]
dxc/dt = (π/12) [ q xc B − x((24/(0.99729 τx))² + k B) ]
B = Gα(1 − n)(1 − 0.4x)(1 − 0.4xc)
α = α0 (I/I0)^p (I in lux, per minute)
dn/dt = 60 [ α(1 − n) − β n ]
μ=0.13 q=1/3 k=0.55 G=33.75 α0=0.05/min I0=9500 lux p=0.5 β=0.0075/min
How the room shows it. Sunlight through the window and the lamps follow the light schedule you set; the wall dial is a 24 h clock (00 at the top) with a ring of lit hours, a white hand for local time and a red marker for the last minimum of x, a proxy for the core-body-temperature minimum. The glowing curve on the pedestal is the live (x, xc, n) trajectory: an entrained clock traces a closed loop, darkness lets it free-run at τx, and a light pulse kicks it off the loop. The blanket glows blue while x < 0 (model biological night).
What you can test: in darkness the period equals τx; near 24 h the clock locks to the schedule; the phase-response curve shows delays before and advances after the x-minimum.
Simplifications: one population-average oscillator of an average adult; no age, chronotype, sleep homeostasis or non-photic cues; light is a plain lux value without spectrum; the 3D room is illustrative, not to scale. Educational model, not medical advice.