Electrodeposition Dendrites

2D companion of the 3D dendrite observatory: ions diffuse toward the electrode, stick at the first contact and the deposit branches into a tree.

Switch to 3D

Presets

Playback

Apparatus

Model checks

The science

What is modelled

Ions are random walkers on a grid with a drift toward the electrode. When a walker touches the deposit it sticks, so the tips, which are reached first, grow fastest and the deposit branches: diffusion-limited aggregation. The panel beside it uses real electrochemistry: the limiting current set by the diffusion layer, Faraday's law for the mass and Sand's time at which the surface runs out of ions.

Equations

  • Limiting current iL = z F D c / δ, with D(T) from an Arrhenius law.
  • Faraday m = M Q / (z F).
  • Sand time τ = π D (z F c / 2J)².
  • Random walk ⟨r²⟩ = 4 D t in 2D; DLA mass M ∝ Rd, d near 1.7.

Checks run in the page

  • Mean squared displacement of unbiased walkers.
  • Faraday mass from summed current.
  • Finite-difference diffusion layer against the Sand time.
  • Fractal dimension of a seeded unbiased aggregate.

Honest simplifications

The lattice has no electric field solver, the voltage only sets a drift and the current-voltage law is a smooth saturating curve, not a Butler-Volmer fit. Lattice time is not mapped to seconds. It is an illustration of why diffusion limits cause dendrites, not a battery-safety model.

What to try
  • Press High voltage, dilute and compare the thin branches with the compact deposit of Low voltage, calm.
  • Raise stirring and see the diffusion layer and the limiting current change.
  • Watch the Sand time fall as the current density rises.