The science
Heat transfer into an insulated load. The cargo space is modelled as three lumped temperatures: the air (Ta), an outer layer of the load (Ts, 30 % of the mass: outer cartons, pallet edges) and the core (Tc, 70 %). Heat enters through the walls with the conductance UA and moves inward through two thermal resistances:
Ca dTa/dt = UAeff (Tamb − Ta) + hA (Ts − Ta) − Qcool
Cs dTs/dt = hA (Ta − Ts) + kc (Tc − Ts) + qresp,s
Cc dTc/dt = kc (Ts − Tc) + qresp,c
Cs + Cc = m cp is the heat capacity of the product (tonnes of food hold megajoules per kelvin), so a stopped refrigeration unit warms the air within minutes, the outer cartons within hours and the core within a day. That lag is why a short excursion on the data logger (air probe) is often harmless, while a long one is not. The time constant of the whole load is τ ≈ m cp/UA. While a door is open the conductance is multiplied by (1 + kdoor), and on a dock with the unit off by (1 + 0.25 kdoor). The unit is a proportional thermostat, Qcool = Qmax d(Tamb) clamp[(Ta − Tset)/band, 0, 1], with its capacity derated by 1.2 % per kelvin above 25 C ambient; the electricity is Qcool/COP with COP = 0.4 Tset/(Tamb − Tset) (about 40 % of the Carnot value, clamped to 0.9..3.5). Phase-change packs are handled with the apparent-heat-capacity method: near the melting point the outer layer gets the extra capacity L m g(T − Tpcm), g a smooth bump of width ±1 K and unit area, with L = 200 kJ/kg, so a pack plateau lasts about L m / (heat leak). Fruit and vegetables also give off respiration heat q = q0 m ebT (strawberries: 0.05 W/kg at 0 C, b = 0.09 per K).
Spoilage kinetics (Arrhenius). The rate of the dominant quality-loss reaction follows k(T) = A exp(−Ea/RT), so relative to storage at the reference temperature the ageing rate is
r(T) = exp[ (Ea/R) (1/Tref − 1/T) ]
With Ea = 90 kJ/mol every 10 K near 5 C multiplies the rate by about 3.7. The fraction of the shelf life that is used up is S = ∫ r(T(t)) dt / SL, where SL is the shelf life (or, for a vaccine, the stability budget) at Tref; the page integrates it separately for the outer layer and the core and weights them 30:70. When S reaches 100 % the verdict is FAIL. A load is also failed when freeze-sensitive goods have an outer layer below −0.5 C for 30 minutes, or (vaccine) when it spends more than 120 minutes above its limit. The mean kinetic temperature (Haynes 1971), MKT = (Ea/R) / (−ln[ mean exp(−Ea/RT) ]), is the constant temperature that would age the product as much as the real, fluctuating one; it is always above the arithmetic mean, to second order by (Ea/R) σ2/(2T2) − σ2/T.
Synthetic shipments. The Monte-Carlo panel simulates the chosen number of shipments in your browser, each with its own seeded weather (mean temperature ±3 K, hour-scale noise), delay (log-normal, up to +80 %), number and length of door openings, load temperature at loading and, with the chosen probability, a refrigeration fault (median 2.5 h) at a random time. The histogram of the used shelf life and the share delivered within specification show what a rule such as "keep the air probe within the band" leaves to chance. The downloadable CSV is a synthetic data-logger record (air and core probes with Gaussian sensor noise); nothing in it is measured data.
Honest simplifications. (1) Three lumped nodes: there is no spatial airflow, no pallet-to-pallet difference and no stratification, so the front-to-back and top-to-bottom gradients of a real trailer are missing; the colours of the cartons only show the outer and the core node. (2) The thermal parameters (hA = 0.12 W/K per kg, kc = 0.05 W/K per kg, air plus structure capacity 3 kJ/K + 40 J/K per kg) are plausible round numbers, not measurements of a particular vehicle. (3) Ea, the reference temperatures and the shelf lives are illustrative values for each product class; the vaccine stability budget (30 days at 5 C) is a teaching number, and real decisions about a vaccine or any food follow the manufacturer's data, the product label and the applicable good-distribution rules. (4) A single reaction describes ageing; real products have several mechanisms, lag phases and growth limits. (5) The thermostat is proportional, not on/off with a defrost cycle. (6) Brands and carriers are not modelled.
Checks run in the page. (a) A passive warm-up over 12 h agrees with the matrix-exponential solution of the same linear three-node system to better than 0.02 K; (b) with the thermostat, the air temperature after 200 h equals the closed form (UA Tamb + K Tset)/(UA + K); (c) with phase-change packs the enthalpy change (including the latent heat from the closed-form integral of g) equals the time-integrated heat flow; (d) a vaccine held at 25 C for a day uses exactly the shelf-life fraction given by the Arrhenius formula; (e) the mean kinetic temperature of a sinusoidal swing matches the second-order estimate, and exceeds the arithmetic mean.