AI Triage Queue 2D

Same patients, two queues: Blender-rendered ward sprites show who waits when an AI score reorders the line.

Switch to 3D

Shift

AI triage

Presets

Playback

Model checks

running...
The science

What is simulated

One clinician sees patients one at a time (a single-server queue). Patients arrive at random (Poisson process, rate λ per hour) and each consultation takes an exponentially distributed time with mean m minutes. The two wards below run the same patients with the same consultation times; only the order of service differs. FIFO serves the longest-waiting patient. AI priority serves the waiting patient with the highest AI urgency score; the score is the patient's hidden true urgency plus Gaussian noise N(0, σ2). A consultation is never interrupted (non-preemptive priority). A patient is urgent when true urgency > 0.75 (about one in five).

The mathematics

Utilisation is ρ = λ m. For FIFO (M/M/1) the mean wait is Wq = ρ m / (1 − ρ). For two non-preemptive priority classes (Cobham 1954) with class-1 load σ1 = ρ p and mean residual work W0 = λ E[S²]/2 = λ m², the class waits are W1 = W0/(1 − σ1) and W2 = W0/((1 − σ1)(1 − ρ)). Kleinrock's conservation law says that with equal service times the load-weighted mean wait is the same as FIFO: p W1 + (1 − p) W2 = ρ m/(1 − ρ). Prioritising does not make the queue shorter; it moves waiting from urgent patients to routine ones.

Independent numerical check

The first check simulates 1.2 million patients headlessly at ρ = 0.8 with a perfect urgent/routine classifier and compares the simulated mean waits with the formulas above (they agree to about 1 %). The other checks are structural: both policies finish the shift at the same minute (work conservation) and a noise-free AI orders urgent patients first (AUC = 1).

Honest simplifications

Real triage (ESI, Manchester) uses vital signs, several clinicians, resus bays, re-triage and patients who leave. Here there is one server, exponential consultations, a synthetic urgency score and a single noise parameter for "AI accuracy"; the 30-minute threshold is illustrative. The shift charts use one random shift (small samples are noisy, so the right-hand chart averages 30 shifts per noise value). This is a queueing lesson, not a clinical tool and not medical advice.

Clock08:00
FIFO waiting0
AI waiting0
Shift0 %
...
Loading...
Wait of each urgent patient: FIFO vs AI
People waiting over the shift
Benefit vs AI quality (mean of 30 shifts)
urgent (true > 0.75)moderateroutinenumbers above patients = AI score (0-100)
Made with 🟠 Blender